With its focused commitment to improving the health and safety of people, Binder's technical solutions are leading the way for safer research environments.
Binder's range of products is suitable for routine applications, highly specialized work in research and development, production and quality assurance.
POCDS is proud to make selected items from the Binder Range available to Australian Laboratories who care about quality research.
BINDER Heating and Drying Ovens
Highest precision for fast drying.
Diversity for all types of thermal: A BINDER heating oven or heating chamber is up to any tasks thanks to its wide temperature range - whether efficient drying, long-term controlled elevated temperatures or sterilisation tasks for homogeneous temperature distribution.
The wide temperature range of the BINDER heating ovens and heating chambers of 5 °C above ambient temperature to 300 °C allows short heating up times and large power reserves.
Whether by gravity or mechanical convection, the high standard of quality and process stability of our heating ovens and heating chambers goes without saying.
BINDER Vacuum Drying Ovens
The standard when it comes to gentle drying
Vacuum drying ovens from BINDER dry samples completely without residues, scaling or oxidation, everything in overdrive.
Thanks to the patented APT.line™ preheating chamber technology, the heat is distributed evenly throughout the electropolished inner chamber and the corrosion-resistant expansion shelf carrier made of stainless steel in the vacuum drying oven. This ensures even, gentle drying.
The vacuum drying ovens of the VDL series with patented flame protection gasket, overpressure encapsulated instrument panel and controlled heating provide additional protection when working with flammable solvents.
BINDER constant climate chambers
Specialists for temperature / humidity / light simulation
A constant climate chamber from BINDER in any implementation is a one-stop solution to easily and reliably manage your stability test or stress test.
The BINDER constant climate chambers of the KBF P series are ideal for norm-compliant work according to ICH guidelines and work independent of water supply. Their special feature: climate and light tests can be performed at the same time in one chamber.
With the KMF, BINDER constant climate chambers offers you a broad temperature and humidity range – created for demanding stress testing.
Heating Ovens
Heating and Drying ovens with natural convection: ED Series
The perfect heating ovens for routine drying and sterilisation applications up to 300 °C.
The strength of the BINDER ED series heating oven: routine drying and sterilisation applications up to 300 °C.
Thanks to the gravity convection, thermal processes are highly efficient for this heating oven.
A BINDER ED heating oven ensures fast, uniform drying.
Performance Characteristics
Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
Temperature range from 5 °C above ambient temperature to 300 °C
Digital temperature setting with an accuracy of one degree
DS control with integrated timer 0 to 99,59 hrs
Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
Optional RS 422 Interface for APT-COM™ Data Control System communication software
Units up to 115 liters are stackable
2 chrome-plated racks included
ED 23 with space-saving door mechanism
BINDER test confirmation
Component
Benefits
Features
APT.line™ for maximum precision
Quick drying
Identical test conditions throughout the chamber interior
Independent of specimen size and quantity
Uniform circulation even under full load
Homogeneous temperature conditions throughout specimen material
Temperature range standard up to 300 °C
Broad range of applications
Short warm up times
Large power reserves
Inner chamber made of stainless steel
Maximum occupational safety
Easy loading and unloading of specimen material
Easy cleaning
Very tight door closure with 2-point door latch
Low heat dissipation due to 60 mm insulation
Rack with tilt protection
No permanent fixtures
Comprehensive equipment standards
Reliable, easy handling
Microprocessor control
Ergonomically positioned controller.
RS 422 interface
PT 100 temperature sensor
Premium quality
Reliable devices with long service lives
Short delivery times
Minimal maintenance and operating costs
Highly automated
Series production
High-quality materials, state-of-the-art production technology
High standard according to DIN 12880 (27-point measurement)
Comprehensive portfolio of accessories and services
Flexible solution in terms of size, type and equipment
Optimal solution for numerous applications
BINDER INDIVIDUAL for customer-specific solutions
Worldwide BINDER Service
Size 23 to 720 liters
Additional product lines with humidity, light, CO2 or vacuum
Voltage variants (UL) and certificates
Various options: Door with viewing window, access ports, reinforced shelves, Data Logger Kits
Worldwide service network
Vacuum Drying Ovens VD | VDL Series
Absolutely Reliable Drying
Both VD and VDL ovens can dry samples completely without residues, scaling or oxidation, and this is achieved in overdrive.
The patented APT.line™ preheating chamber technology distributes the heat isd evenly throughout the chamber and the stainless steel expansion shelf carrierin the vacuum drying oven. This ensures even, gentle drying.
Depending on your individual safety requirements, our unique safety concept sets a new standard and is combined with a first-rate performance and quality.
Features of excellence in controlled sample drying
Gentle Drying Process
Gentle drying throughout the chamber interior
Direct heat transfer through large thermal conducting plates
Patented, flexible positioning of the expansion racks
Binder's Safety Standard Inclusions
Ex classification of the inner chamber according to ATEX Directive 94/9/EC: II -3G IIB T3-T1 Gc X
Spring-mounted safety glass panel with shatter protection
Standard inert gas connection for interior flushing
Electronic components are decoupled from the inner chamber
Accelerated Drying Process
BINDER Cross-Flow Principle
Even flow throughout the inner chamber from bottom to top
Finely adjustable inert gas valve without turbulence for lighter samples
Individually controlled
Easy to Clean Chambers
Smooth inner chamber with rounded corners
Inner chamber and all connections made of highly corrosion resistant stainless steel V4A
Fixtures are fully removable
VD Series
Vacuum Drying Ovens for NON-flammable Solvents
Standard Equipment
Program Controller
Inert gas valve with Cross-Flow Technology
Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
Analog pressure gauge
Micro-polished inner chamber, suction and ventilation tubes, pressure container, expansion racks and ball valve are made of highly corrosion resistant stainless steel V4A
Door gasket made of tempered silicone
RS 422 interface for APT-COM™ DataControlSystem communication software
Two patented aluminum expansion racks with flexible positioning
Integrated weekly program timer with real-time function
Two × 24 V DC (max 0.4 A) switching outputs, switched via two control contacts in the program editor
Safety concept:
Spring-mounted safety glass panel with shatter protection
Inert gas connection for interior flushing
VDL Series
Safety Vacuum Drying Ovens for FLAMMABLE Solvents
Standard Equipment
Program Controller
Inert gas valve with Cross-Flow Technology
Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
Analog pressure gauge
Micro-polished inner chamber, suction and ventilation tubes, pressure container, expansion racks and ball valve are made of highly corrosion resistant stainless steel V4A
Door gasket made of tempered silicone
RS 422 interface for APT-COM™ DataControlSystem communication software
Two patented aluminum expansion racks with flexible positioning
Integrated weekly program timer with real-time function
Extended safety concept:
Spring-mounted safety glass panel with shatter protection
Inert gas connection for interior flushing
Pressure control device for heating activated < 125 mbar
Over pressure capsuled instrument panel with compressed air connection and maintenance unit
Flame protection gasket
ATEX Directive 94/9/EC: II -3G IIB T3-T1 Gc X
Avoiding of explosive atmosphere
Avoiding of ignition source
Limitation of the effect of possible explosions to a harmless level
Constant Climate Chambers
KBF series
The KBF is the specialist for reliable stability testing and precise maintenance of constant climatic conditions. From programming to documentation, it meets all important guidelines such as ICH, FDA, GMP and GLP. With its high capacity reserves, automatic water and wastewater management and many options, the BINDER KBF is well prepared for the future.
MCS Controller with 25 storage programs, each with 100 segments, for a maximum of 500 program segments
User-friendly LCD monitor
Easy-to-use menu control
Integrated electronic chart recorder
Variety of options for graphic representation of process parameters
Real-time clock
Microprocessor controlled humidification and dehumidification system with a drift-free, capacitive humidity sensor
Inner glass door with sealing
Independent adjustable temperature safety device, class 3.1 (DIN 12880) with optical and acoustic alarm
Access port with silicone plug Ø 30 mm, left side
Complete safety connection kit for water supply up to 1 m height
Ethernet interface for communication software APT-COM™ DataControlSystem
2 stainless steel racks
BINDER test certificate
Options
Various access ports, Data Logger Kits, BINDER PURE AQUA Service, external water supply kit, APT-COM™ DataControlSystem, qualification documentation package, etc…
Constant climate chambers with light | KBF P | LQC series
Our expert for photostability testing. In terms of standards compliance, performance and functionality, the KBF P is a true KBF and is also equipped with ICH-compliant illumination. This provides clear and meaningful test results according to ICH guideline Q1B, Option 2. The variable position illumination cassettes with the unique BINDER Q1B Synergy Light™ ensure homogeneous lighting conditions over the entire usable area.
Equipment
Temperature range 0 °C to 70 °C (without illumination and humidity)
Temperature range 10 °C/20 °C with 60 °C (with illumination and humidity)
Humidity range 10 % to 75 % r. H. (with illumination)
Humidity range 10 % to 80 % r. H. (without illumination)
Variable position illumination cassettes with BINDER Q1B Synergy Light™
MCS controller which can store 25 programs of 100 sections each for a maximum of 500 program segments
User-friendly LCD color screen
Easy-to-read menu guide
Integrated electronic chart recorder
Variety of options for the graphic display of process parameters
Real-time clock
Electronically controlled humidification and dehumidification system with capacitive humidity sensor
Suitable for stability tests according to ICH guideline Q1A(R2) and Q1B Option 2
Inner glass door with seal
Independent temperature safety device class 3.1 (DIN 12880) with visual and audible alarm
Access port with silicone plug Ø 30 mm, left side
Complete safety connection kit for water supply and drainage, up to 1 m high
Ethernet interface for communication software APT-COM™ DataControlSystem
Shelves, stainless steel
Options
Various access ports, Data Logger Kits, BINDER PURE AQUA Service, external water supply kit, APT-COM™ DataControlSystem, qualification documentation package, etc…
Constant climate chambers | KMF series
The KMF is the specialist for unconditionally reliable stress testing and precise maintenance of constant test conditions. It has particularly large power reserves and an extremely broad climate range: from -10 °C to 100 °C. It works condensation-free up to 90% r. H. These features make the KMF unique in its class.
Equipment
Temperature range from -10 °C to 100 °C
Humidity range 10 % to 90 % r. H.
MCS controller which can store 25 programs of 100 sections each for a maximum of 500 program segments
User-friendly LCD color screen
Easy-to-read menu guide
Integrated electronic chart recorder
Variety of options for the graphic display of process parameters
Real-time clock
Electronically controlled humidification and dehumidification system with capacitive humidity sensor
Inner glass door
Independent temperature safety device class 3.1 (DIN 12880) with visual and audible alarm
Access port with silicone plug Ø 30 mm, left side
Complete safety connection kit for water supply and drainage, up to 1 m in height
Ethernet interface for communication software APT-COM™ DataControlSystem
Shelf, stainless steel
Four casters, two with brakes (KMF 240/720)
Options
Various access ports, Data Logger Kits, BINDER PURE AQUA Service, external water supply kit, APT-COM™ DataControlSystem, qualification documentation package, etc…