Eppendorf Australian Distributor - POCD Scientific - click for home pageEppendorf Australian Distributor - POCD Scientific header banner
site search heading
search

POCD Scientific Specials
  • EOFY Specials
  • Microcentrifuge Bonus
  • 58XX Centrifuge
           Free goods & Discount
  • PCR Solutions Bonuses
  • Eppendorf Advantage
  • 2013 Trade in/up offers

  • New Products at POCDS
  • Feather Microtome blades
          in a disposable dispenser
  • Xplorer Plus Electronic
         Automatic Pipette
  • Tharmac Cellspin I
  • Tharmac Cellspin II
  • Tharmac Cellstain 15
  • Tharmac Cellstain 7
  • Tharmac Cellstain 6
  • Tharmac Consumables
  • Centrifuge 5427R
  • AnD Scientific balances
  • qTower Rapid qPCR
  • Rockers/shakers/mixers
  • Buhler Mixers
  • PCR: Mastercycler Nexus
  • VIAFLO 384 tip semi-
         automated plate pipetting
  • VIAFLO 96 tip semi-
         automated plate pipetting
  • Voyager variable-
         spacing pipette
  • Water Baths
  • Bead Baths
  • Deepwell plates
  • Polypropylene Microplate
  • Real-time PCR plates

  • Best Sellers: Quick links to POCD Scientific most sought-after products
  • Centrifugation
  • Combitips Advanced
  • Micro centrifuge
  • Compact Benchtop
  • Multi-purpose Centrifuge
  • Pipette Starter Pack
  • Eppendorf pipettes
  • Multichannel  Pipette
  • Electronic  Pipette
  • Multipette repeating
  • PCR tubes
  • Microcentrifuge tubes


  • Eppendorf Liquid Handling Pipettes logo
  • Centrifugation
  • Pipettes, Dispensers
  • Consumables & more
  • Tips, Tubes and Plates
  • Find the Right Tube!
  • PCR
  • Temp control & mixing
  • Spectrophotometer
  • BioSpectrometer
  • MicroManipulation
  • Technical Service
  • Electroporation
  • Vacuum Concentration



  • spacer-force 150px wide
    spacer force 10px, 750 deep wide spacer-force 840px wide
    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus

    easy, rapid, reliable stand-alone Spectrophotometry Analysis

    142

    We sell, supply, service and carry spare parts for these products.
    All equipment servicing to manufacturer’s specs by Eppendorf factory certified technicians. Calibration, repair, service, spare parts, Compliance Covering - IQ/OQ/PQ, calibration and validations. On-site repairs are available for customers in Sydney, Melbourne and Brisbane. For other areas/States, we offer a workshop service or spare parts.

    overview features technical ordering consumables adapter

    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ overview

    this is a critical productThese are POCDS Time Critical Products - we are seriously committed to having these products in stock 24/7/365 for immediate shipping. If we are unable to immediately dispatch any of these items to you upon receiving your order we will airfreight the item from Germany at our expense to minimise the delay in getting the item to you.


    BioPhotometer plus

    With the stand-alone spectrophotometer, the BioPhotometer plus, Eppendorf offers a compact fully self-contained UV/Vis spectrophotometer for use in molecular biology, biochemistry and cell biology.

    The photometer provides instant, out-of-the-box access to 32 routine methods, of which 9 methods are freely programmable, eg:

    • Measurement of DNA, RNA and protein concentration (UV and colorimetric) - also known as dna quantitation, rna quantitation and protein quantitation
    • Incorporation rate of fluorescent molecules (550 nm/650 nm), eg for microarray experiments
    • Enzymatic assays (e.g., peroxidase, alkaline phosphatase, β-galactosidase)
    • Optical density of cells (OD 600)

    Both measurement (quantitation) and calculation of results are performed at the press of a button, and the results of the spectrophotometric analysis, as well as all accompanying quantitaion data, are available at a glance. This guarantees safe, error-free operation and reliable results.

    In addition to its low weight, the spectrophotometer is small, yet extremely sturdy due to a robust metal housing, which allows for easy transport and cleaning.

    Eppendorf's stand-alone spectrophotometer has practical advantages over such popular spectrophotometers as the nanodrop and nanophotometer. Whereas the nanodrop and nanophotometer require connection to a computer and specific software to carry out the spectrophotometric analysis, Eppendorf's Biophotometer plus carries out the quantitation analysis by itself

    The BioPhotometer plus is designed for use with cuvettes such as the Eppendorf UVette®, but is also optimized for measurement of small volumes through the use of microliter cells such as Hellma® TrayCell.

    The new BioPhotometer data transfer software can now be used to download/transfer all measurement, quantitation and calibration data to a PC. Besides enabling the printing of results it also allows results to be exported to data processing software for further evaluation.

    The program also offers the option of data archiving, which can be clearly configured with an optional user administration.





    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ features



    BioPhotometer plus Applications
    • Quantification / quantitation of nucleic acids (dsDNA, ssDNA, RNA, Oligo)
    • Quantification / quantitation of proteins (280 nm, Bradford, Lowry, BCA)
    • Cell density measurement (OD600)
    • NEW - Incorporation rate of fluorescent dyes (dye 550/650, e.g., Cy-3, Cy-5)
    • NEW - Enzymatic assays: endpoint detection (e.g., of enzyme activities or cell biological assays)
    • NEW - Direct absorbance measurement of single wavelengths without any calculation (230 nm, 260 nm, 280 nm, 340 nm, 405 nm, 490 nm, 550 nm, 595 nm, 650 nm)
    Features
    • Fully self-contained - does NOT require PC to function
    • 9 wavelengths suitable for the common methods in molecular biological, biochemical and cell biological labs
    • Preprogrammed methods for quantification of nucleic acids and proteins as well as incorporation rate of fluorescent dyes
    • Automatic calculation of dilution factors
    • Assays at 340 nm, 405 nm, and 490 nm are user defined for highest flexibility
    • Measurement of single wavelengths without any calculation
    • Storage of the last 100 results and all corresponding data
    • Simple user guidance for error-free operation
    • Different colored function keys for easy operation
    • Compact design and robust housing
    • Stand-alone unit without need for PC connection
    • No pre-warming saves time
    • Xenon flash lamp with long lifetime and high light intensity
    • No moving parts – less service needs

    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ technical



    Optical system:

    Absorption singlebeam photometer with reference beam

    Light source: Xenon flash lamp
    Light beam height: 8.5 mm
    Measuring wavelengths: 230, 260, 280, 340, 405, 490, 550, 595, 650 nm
    Spectral bandwidth:

    5 nm at 230–340 nm, 7 nm at 405–650 nm

    Wavelength systematic error:

    ±1 nm at 230–280 nm, ±2 nm at 340–650 nm

    Photometric measuring range:

    0 to 3 A (2 A at 340 nm); Dye Methods: 2 A at 550 nm/650 nm

    Photometric random error: ±0.002 A at 0 A; ±0.005 A at 1 A
    Photometric systematic error:

    ±1 % at 1 A

    Method dependent calculation:
    • Absorbance
    • Concentration via factor
    • Concentration via calibration with 1 to 10 standards
    • One point calibration (1 standard)
    • Linear regression (2 to 10 standards)
    • Nonlinear regression (3rd degree polynom; 4 or 5 to 10 standards), 1 x, 2 x or 3 x determination
    • Ratio 260/280, ratio 260/230, molar concentration, total yield
    • For dye methods: FOI (frequency of incorporation)
    Calibration memory:

    For all calibration procedures

    Results memory: For 100 results with absorbance and ratio values, sample number, sample dilution, date and time
    Interface: RS232C, serial, PC connection optional
    Power requirement: Approx. 20 W in operation, approx. 10 W in Standby mode
    Power supply: 100–240 V, ±10 %; 50–60 Hz, ±5 %
    Dimensions (W x D x H): 20 x 32 x 10 cm
    Weight: 3 kg
    Accessories:

    Thermal printer DPU 414, 40 characters/line; Secondary UVVIS filter set for verifying photometric and wavelength accuracy (NIST traceable)

    Cuvettes: UVette, Hellma TrayCell*, and common rectangular cuvettes of suitable glass or plastic materials

    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ ordering

    Please
    note:
    We have endeavoured to provide Australian catalogue numbers; however it would be prudent to verify any catalogue numbers taken straight from our site with POCD Scientific before using them to place an order.

    We are seriously committed to having these product in stock 24/7/365 for immediate shipping. However we do need to acknowledge that spikes of demand can temporarily deplete our normally robust stock levels. If such a situation affects your order we will airfreight the item from Eppendorf at our expense to minimise the delay in getting the item to you.


    Description Order no.
    BioPhotometer plus, 230 V/50–60 Hz 6132 000.008
    Secondary UV-VIS filter test set for verifying photometric precision and wavelength accuracy (NIST traceable) 6131 928.007
    Thermal printer DPU 414, incl. power supply 230 V and printer cable 6131 011.006
    Thermal paper (5 rolls) 0013 021.566
    UVette®, individually packaged single cuvettes,
    certified RNase, DNA and proteinfree, 80 pcs.
    0030 106.300
    UVette routine pack, Eppendorf Quality purity level,
    reclosable box, 200 pcs.
    0030 106.318
    BioPhotometer Data Transfer Software 6132 854.007

    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ consumables



    Eppendorf Uvette The Eppendorf UVette® fulfils the highest specifications of modern spectrophotometric analysis in the UV range and can be optimally used for sensitive samples and small volumes.

    read about POCD Scientifics best-selling Cuvette
    the Eppendorf UVette®



    Spectrophotometer (spectro) Eppendorf's BioPhotometer plus ~ the Uvette adapter



    the UVette is inserted with the aid of an adapter

    Description of the Adapter

    The UVette is ideal for use with the Eppendorf BioPhotometer plus. In other common photometers and/or spectrophotometers, the UVette is inserted with the aid of an adapter, which performs two functions:

    • It aligns the UVette to the height of the photometer’s light beam
    • Diaphragm function for an optimal distribution of light








    Compatibility list:
    Which adapter for which device?


    Manufacturer Device UVette adapter/size Comments
    Varian Cary 50 15 mm Proven by customers.
    Cary 100 8.5 mm -
    GE Healthcare GeneQuant® I/II GeneQuant I/II -
    GeneQuant devices other than GeneQuant I/II 15 mm -
    Ultrospec series 15 mm -
    GeneQuant™ 1300 15 mm -
    Agilent/

    Hewlett Packard
    8452A UV-Vis spectroscopy system 15 mm Proven by customers
    Agilent Technologies 8453 UV-Visible Spectrophotometer 15 mm Proven by customers.
    Analytik Jena SPECORD series 8.5 mm or 15 mm When using the adjustable cuvette holder for 8.5 mm or 15 mm light path height.
    SPEKOL series 8.5 mm When using the adjustable cuvette holder for 8.5 mm or 15 mm light path height.
    Biochrom® Libra S21/S22 15 mm -
    Libra S32/S32PC 15 mm -
    Eppendorf BioPhotometer / BioPhotometer plus - No adapter is required.
    Hitachi® UV-series UBA 410–1500 Only available in Europe. For further information: support@eppendorf.com
    Hitachi U1800 15mm Proven by customers.
    Hitachi U2900 10mm Proven by customers.
    GeneSpec I/II UBA 410–1500 Only available in Europe. For further information: support@eppendorf.com
    Implen NanoPhotometer™ 15mm -
    Jenway Genova Adapter from Jenway Please contact your local Techne or Jenway representative.
    PerkinElmer® Lambda series, except EZ series 15 mm -
    Lambda EZ 201 and EZ 210 8.5 mm When using the micro cell holder.
    Secomam UVIKON series 15 mm When using the single-cell holder. For models 943 and XL, the 15 mm adapter can also be used for multi-cell holder 6 x 6.1.
    Shimadzu® UV-series 15 mm When using the standard cell holder.
    UV Multispec-1500 15 mm -
    BioSpec® 15 mm -
    Techne® Genova Adapter from Jenway Please contact your local Techne or Jenway representative.
    Specgene Adapter from Jenway Please contact your local Techne or Jenway representative.
    Thermo Fisher Scientific BioMate series 15 mm When using the single-cell holder.
    Helios series 15 mm When using the single-cell holder.
    Genesys 10S - Proven by customers.
    NanoDrop 2000c - See recommendations NanoDrop 2000/ 2000c User Manual (V 1.0).

    This adapter list provides an overview of the correct adapter for use with Eppendorf’s UVette® in devices from other manufacturers. No adapter is required for use in Eppendorf’s photometers.

    The adapters’ compatibility with the devices from other manufacturers has been jointly tested by Eppendorf, the device manufacturers and our customers.


    Back to top or call 1800 640 075 free


    Middle Path Online logo website by
    Middle Path Online
    pocdscientific.com.au/spectrophotometer_spectro_photometry.php       updated August 22nd,2012
    ©2013 POCD Pty Ltd,     T/A POCD Scientific ABN 93 067 939 824
    product information, images and video gratefully used with permission of manufacturers.