Eppendorf Xplorer® & Xplorer® Plus Automatic Electronic pipette
multi-award-winning design, exacting standards, optimal support ~ Simply Better Pipetting
|
|
|
|
|
|
|
Save even more than 28%!!
POCDS can offer very substantial further discounts for bulk orders/ special pricing/ package deals on the full range of Eppendorf pipettes (Includes Eppendorf Research plus pipettes: Research Pack starter kits; Research plus single and multi-channel; Xplorer manual and electronic; Easypet pipette boys, Multipette dispensers, Varispenser bottle top dispensers; Stream and Xstream electronic dispensers etc
Please visit our Bulk Liquid Handling Deals page to make an enquiry
for special pricing/package deals/bulk pricing on these products
| overview |
features |
technical |
ordering |
consumables |
downloads |
FAQ answers |
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ overview |
 | These are POCDS Time Critical Products - we are seriously committed to having these products in stock 24/7/365 for immediate shipping. If we are unable to immediately dispatch any of these items to you upon receiving your order we will airfreight the item from Germany at our expense to minimise the delay in getting the item to you. |
You know a product is the undisputed best of its class when it continues to win professional accolades such as these
- 2010: Red Dot (“best of the best”) trendsetting design award
- 2010: Golden Pin Design Award for design excellence
- 2011: iF Product Design Award for innovative product design.
- 2011: Scientist's Choice Award “Best New General Lab Product of 2010”
You also know the results you obtain when using the best product are as good as the product: simply the best. And we haven't even mentioned the fulfilling feeling of using a prestigious award-winner: its like driving a Rolls-Royce Ghost Passenger Car - another winner of the 2010 Red Dot award.
People who give 100% every day deserve the best tool and the best equipment. You work on demanding problems and important decisions depend on the results of your work. Your standard is extremely high and your performance is professional.
The new Eppendorf Xplorer ® automatic electronic pipette was specially designed for high professional standards to provide optimal support for you in your work, with a new intuitive operating concept and design based on the proven Eppendorf PhysioCare Concept ®.
These features set new standards for simplicity, precision and reproducibility, which means no more delays due to complicated programming or inflexible processes. Instead, you get precisely adjustable parameters, maximum reproducible results, fatigue-free work and consistent, full control over the pipetting processes
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ features |
Eppendorf Xplorer®/Xplorer® plus
Work intuitively
- Multifunctional rocker: „Up is up and down is down“™ principle
- Easy selection of all functions with the practical selection dial
- Operate in the language of your choice
- Clearly arranged color display
- No sub-menues
- Help function
- Innovative rocker: When the tip is ejected, the piston automatically returns to zero position
PhysioCare Concept®
- Reduced weight
- Improved ergonomics
- Perfect balance
- Optimally angled pipette head
- Improved view & high resolution display
- Spring-loaded tip cone provides maximum tightness
Reliably reproducible results
- Tips always rest in the same position
- Volume & speed precisely und reproducibly adjustable
- Adjustable to your work environment and requirements
Additional Features of the Eppendorf Xplorer plus:
- On/off switch: Switches the pipette off during longer periods of inactivity
- Additional applications: Aspirating, diluting, sequential dispensing and reverse pipetting
- Programming: One-time programming of sequences for easier handling of complex processes
- Individual fixed volume setting: Desired volume can be saved
- Password protection: Protects programming and adjustment
- Password protection: Protects programming and adjustment
- Individual speed setting: Sets parameters to your individual working speed
- Display of service intervals: Pipette maintenance reminder function, based on time or frequency of use as desired
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ technical |
| Volume range |
Volume |
Systematic deviation |
Random deviation |
| Medium gray multi-function rocker for 20 μL |
| 0,5–10 μl |
1 μl |
±2,5 % |
±0,025 μl |
±1,8 % |
±0,018 μl |
| |
5 μl |
±1,5 % |
±0,075 μl |
±0,8 % |
±0,04 μl |
| |
10 μl |
±1,0 % |
±0,1 μl |
±0,4 % |
±0,04 μl |
| Yellow multi-function rocker for 200 μL |
| 5–100 μl |
10 μl |
±2,0 % |
±0,2 μl |
±1,0 % |
±0,1 μl |
| |
50 μl |
±1,0 % |
±0,5 μ |
±0,3 % |
±0,15 μl |
| |
100 μl |
±0,8 % |
±0,8 μl |
±0,2 % |
±0,2 μl |
| Orange multi-function rocker for 300 μL |
| 15–300 μl |
30 μl |
±2,5 % |
±0,75 μl |
±0,7 % |
±0,21 μl |
| |
150 μl |
±1,0 % |
±1,5 μl |
±0,3 % |
±0,45 μl |
| |
300 μl |
±0,6 % |
±1,8 μl |
±0,2 % |
±0,6 μl |
| Blue multi-function rocker for 1,000 μL |
| 50–1.000 μl |
100 μl |
±3,0 % |
±3 μl |
±0,6 % |
±0,6 μl |
| |
500 μl |
±1,0 % |
±5 μl |
±0,2 % |
±1 μl |
| |
1.000 μl |
±0,6 % |
±6 μl |
±0,2 % |
±2 μl |
| Violet multi-function rocker for 5 mL |
| 0,25–5 ml |
500 μl |
±3,0 % |
±15 μl |
±0,6 % |
±3 μl |
|
2.500 μl |
±1,2 % |
±30 μl |
±0,3 % |
±6,25 μl |
| |
5.000 μl |
±0,6 % |
±30 μl |
±0,15 % |
±7,5 μl |
| Turquoise multi-function rocker for 10 mL |
| 0,5–10 ml |
1.000 μl |
±3,0 % |
±30 μl |
±0,6 % |
±6 μl |
| |
5.000 μl |
±0,8 % |
±40 μl |
±0,2 % |
±10 μl |
| |
10.000 μl |
±0,6 % |
±60 μl |
±0,15 % |
±15 μl |
|
|
Multi-channel Eppendorf Xplorer® (incl. charger)
| Volume range |
Volume |
Systematic deviation |
Random deviation |
| Medium gray multi-function rocker for 20 μL |
| 0,5–10 μl |
1 μl |
±5,0 % |
±0,05 μl |
±3,0 % |
±0,03 μll |
| |
5 μl |
±1,5 % |
±0,075 μl |
±0,8 % |
±0,04 μl |
| |
10 μl |
±1,0 % |
±0,1 μl |
±0,4 % |
±0,04 μl |
| Yellow multi-function rocker for 200 μL |
| 5–100 μl |
10 μl |
±2,0 % |
±0,2 μl |
±2,0 % |
±0,2 μl |
| |
50 μl |
±1,0 % |
±0,5 μ |
±0,8 % |
±0,4 μl |
| |
100 μl |
±0,8 % |
±0,8 μl |
±0,25 % |
±0,25 μl |
| Orange multi-function rocker for 300 μL |
| 15–300 μl |
30 μl |
±2,5 % |
±0,75 μl |
±1,0 % |
±0,3 μl |
| |
150 μl |
±1,0 % |
±1,5 μl |
±0,5 % |
±0,75 μl |
| |
300 μl |
±0,6 % |
±1,8 μl |
±0,25 % |
±0,75 μl |
| Green multi-function rocker for 1,200 μL |
| 50–1.200 μl |
120 μl |
±6,0 % |
±7,2 μl |
±0,9 % |
±1,08 μl |
| |
600 μl |
±2,7 % |
±16,2 μl |
±0,4 % |
±2,4 μl |
| |
1.200 μl |
±1,2 % |
±14,4 μl |
±0,3 % |
±3,6 μl |
The data for systematic and random deviations only applies when using Eppendorf epT.I.P.S.® pipette tips.
|
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ ordering |
Please note: | We have endeavoured to provide Australian catalogue numbers; however it would be prudent to verify any catalogue numbers taken straight from our site with POCD Scientific before using them to place an order.
We are seriously committed to having these product in stock 24/7/365 for immediate shipping. However we do need to acknowledge that spikes of demand can temporarily deplete our normally robust stock levels. If such a situation affects your order we will airfreight the item from Eppendorf at our expense to minimise the delay in getting the item to you. |
Single-channel Eppendorf Xplorer® (incl. charger)
| Volume range |
Volume |
Order no. |
| Medium gray multi-function rocker for 20 μL |
| 0,5–10 μl |
1 μl |
4861 000.015 |
| |
5 μl |
|
| |
10 μl |
|
| Yellow multi-function rocker for 200 μL |
| 5–100 μl |
10 μl |
4861 000.023 |
| |
50 μl |
|
| |
100 μl |
|
| Orange multi-function rocker for 300 μL |
| 15–300 μl |
30 μl |
4861 000.031 |
| |
150 μl |
|
| |
300 μl |
|
| Blue multi-function rocker for 1,000 μL |
| 50–1.000 μl |
100 μl |
4861 000.040 |
| |
500 μl |
|
| |
1.000 μl |
|
| Violet multi-function rocker for 5 mL |
| 0,25–5 ml |
500 μl |
4861 000.058 |
|
2.500 μl |
|
| |
5.000 μl |
|
| Turquoise multi-function rocker for 10 mL |
| 0,5–10 ml |
1.000 μl |
4861 000.066 |
| |
5.000 μl |
|
| |
10.000 μl |
|
|
Multi-channel Eppendorf Xplorer® (incl. charger)
| Volume range |
Volume |
Order no.
8-channel |
Order no.
12-channel |
| Medium gray multi-function rocker for 20 μL |
| 0,5–10 μl |
1 μl |
4861 000.104 |
4861 000.112 |
| |
5 μl |
|
|
| |
10 μl |
|
|
| Yellow multi-function rocker for 200 μL |
| 5–100 μl |
10 μl |
4861 000.120 |
4861 000.139 |
| |
50 μl |
|
|
| |
100 μl |
|
|
| Orange multi-function rocker for 300 μL |
| 15–300 μl |
30 μl |
4861 000.147 |
4861 000.155 |
| |
150 μl |
|
|
| |
300 μl |
|
|
| Green multi-function rocker for 1,200 μL |
| 50–1.200 μl |
120 μl |
4861 000.163 |
-- |
| |
600 μl |
|
|
| |
1.200 μl |
|
|
|
Eppendorf Xplorer® plus, single-channel (incl. charger)
| Volume range |
Volume |
Order no. |
| Multifunctional rocker medium gray for epT.I.P.S.® 20 μL |
| 0.5–10 μl |
1 μl |
4861 000.708 |
| |
5 μl |
|
| |
10 μl |
|
| Multifunctional rocker yellow for epT.I.P.S.® 200 μL |
| 5–100 μl |
10 μl |
4861 000.716 |
| |
50 μl |
|
| |
100 μl |
|
| Multifunctional rocker orange for epT.I.P.S.® 300 μL |
| 15–300 μl |
30 μl |
4861 000.724 |
| |
150 μl |
|
| |
300 μl |
|
| Multifunctional rocker blue for epT.I.P.S.® 1,000 μL |
| 50–1,000 μl |
100 μl |
4861 000.732 |
| |
500 μl |
|
| |
1,000 μl |
|
| Multifunctional rocker violet for epT.I.P.S.® 5 mL |
| 0.25–5 ml |
500 μl |
4861 000.740 |
|
2,500 μl |
|
| |
5,000 μl |
|
| Multifunctional rocker turquoise for epT.I.P.S.® 10 mL |
| 0.5–10 ml |
1,000 μl |
4861 000.759 |
| |
5,000 μl |
|
| |
10,000 μl |
|
Eppendorf Xplorer® plus, multi-channel (incl. charger)
| Volume range |
Volume |
Order no.
8-channel
|
Order no.
12-channel |
| Multifunctional rocker medium gray for epT.I.P.S.® 20 μL |
| 0.5–10 μl |
1 μl |
4861 000.767 |
4861 000.775 |
| |
5 μl |
|
|
| |
10 μl |
|
|
| Multifunctional rocker yellow for epT.I.P.S.® 200 μL |
| 5–100 μl |
10 μl |
4861 000.783 |
4861 000.791 |
| |
50 μl |
|
|
| |
100 μl |
|
|
| Multifunctional rocker orange for epT.I.P.S.® 300 μL |
| 15–300 μl |
30 μl |
4861 000.805 |
4861 000.813 |
| |
150 μl |
|
|
| |
300 μl |
|
|
| Multifunctional rocker medium green for epT.I.P.S.® 1,200 μL |
| 50–1,200 μl |
120 μl |
4861 000.821 |
4861 000.830 |
| |
600 μl |
|
|
| |
1,200 μl |
|
|
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ consumables |
Eppendorf Research® plus standard Pipette Tips
| epTIPS |
Purity |
Packaging |
Ordering no. |
|
| 0.1-10 µL, 34 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.811 |
| Reloads |
|
10 trays of 96 tips = 960 tips** |
0030 073.363 |
|
Reloads
|
PCR-clean |
10 trays of 96 tips = 960 tips** |
0030 073.746 |
|
Box
|
|
1 reusable box incl. 96 tips |
0030 073.002 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.207 |
|
| 0.1-20 µL, 40 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.838 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.380 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.762 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.029 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.223 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.019 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.005 |
|
| 0.5-20 µL, 46 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.854 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.401 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.789 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.045 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.240 |
|
| 2-200 µL, 53 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.870 |
| Reloads |
|
10 trays of 96 tips = 960 tips** |
0030 073.428 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips** |
0030 073.800 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.061 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.266 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.035 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.021 |
|
| 20-300 µL, 55 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.897 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.444 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.827 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.088 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.282 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.048 |
|
| 50-1,000 µL,71 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.919 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.460 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.843 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.100 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.304 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.051 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.064 |
|
| 50-1,250 µL, 76 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.935 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.487 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.860 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.126 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.320 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.080 |
|
| 50-1,250 µL, 103 mm (eLongated) |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.730 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.606 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.614 |
| Racks |
|
5 racks of 96 tips = 480 tips |
0030 075.129 |
| Racks |
PCR-clean |
5 racks of 96 tips = 480 tips |
0030 075.129 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.129 |
|
| 500-2,500 µL, 115 mm |
 |
| Standard |
|
5 bags of 100 tips = 500 tips |
0030 000.951 |
| Reloads |
|
10 trays of 48 tips = 480 tips |
0030 073.509 |
| Reloads |
PCR-clean |
10 trays of 48 tips = 480 tips |
0030 073.886 |
| Box |
|
1 reusable box incl. 48 tips |
0030 073.142 |
| Set |
|
1 reusable box incl. 5 trays of 48 tips |
0030 073.347 |
| Racks |
Biopur |
5 racks of 48 tips = 240 tips |
0030 075.102 |
|
| 100-5,000 µL, 120 mm |
 |
| Standard |
|
5 bags of 100 tips = 500 tips |
0030 000.978 |
| Box |
|
1 reusable box incl. 24 tips |
0030 073.169 |
|
| 1-10 ml, 165 mm |
 |
| Standard |
|
2 bags of 100 tips = 200 tips |
0030 000.765 |
| Racks |
Biopur |
5 racks of 24 tips = 120 tips |
0030 075.145 |
|
| 1-10 ml L, 243 mm |
 |
| Standard |
|
2 bags of 100 tips = 200 tips |
0030 000.781 |
* All pipette tips meet the "Eppendorf Quality" purity standard.
** Packed in the form of a stack. All non-marked epTIPS Reloads are packed dual-sided |
|
Eppendorf epTips – DualFilter Tips
| Ordering information |
| |
| ep Dualfilter T.I.P.S. sizes |
International Order No. |
| |
| 0.1 – 10 µl S |
 |
0030 077.504 |
| |
| 0.1 – 10 µl M |
 |
0030 077.512 |
| |
| 0.5 – 20 µl L |
 |
0030 077.520 |
| |
| 2 – 20 µl |
 |
0030 077.539 |
| |
| 2 – 100 µl |
 |
0030 077.547 |
| |
| 2 – 200 µl |
 |
0030 077.555 |
| |
| 20 – 300 µl |
| |
 |
0030 077.563 |
| |
| 50 – 1,000 µl |
 |
0030 077.571 |
| |
| 50 – 1,250 µl |
 |
0030 077.750 |
| |
| 100 – 5,000 µl |
 |
0030 077.580 |
| |
| 1 – 10 ml L |
| |
 |
0030 077.598 |
|
Please Note: |
- The international order numbers for the ep Dualfilter T.I.P.S. have changed.
- Technical specifications subject to change.
|
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ downloads |
| Document |
Size |
download |
| Simply Better Pipetting |
3.7 MB |
 |
| Eppendorf SOP - Standard Operating Procedure for pipettes |
4 MB |
 |
| Eppendorf Xplorer Automatic Electronic Pipette - Operating Manual |
6 MB |
 |
| Eppendorf Xplorer Automatic Electronic Pipette - Short Instructions |
3 MB |
 |
| Charger Stand Carousel |
362 KB |
 |
| Adjustment |
1 MB |
 |
These are PDF files, to obtain a free Adobe PDF reader:  |
 POCD Scientific ~ Eppendorf’s Australian distributor for Xplorer® Automatic Electronic pipettes ~ FAQs |
| Can the Xplorer be autoclaved, and how often? |
 |
"The lower part of the Xplorer can be autoclaved.
175 autoclaving cycles (121 °C, 1 bar, 20 min.) were tested.
The number of the corresponding tests corresponds to an average 5-year use of the pipette."
| Is the Xplorer resistant to solvents? |
 |
"Yes, the Xplorer is resistant to solvents.
Only the display cannot come into contact with the solvent."
| Can the Xplorer be used to dispense acids? |
 |
"Yes, acids can be dispensed with the Xplorer.
But their higher density must be taken into consideration and the Xplorer should be adjusted to the changed physical data in the ""Options"" operating mode."
| Can the Xplorer be readjusted? |
 |
"Yes, there are several options for adjusting the pipette in the Options operating mode, e.g. to ethanol 75 %25 or gylcerol 50 %25.
Furthermore, individual adjustments are possible, as 1-point,
2-point or 3-point settings."
| Which volumes are used for mixing in the "Pipetting and mixing" function? |
 |
In the "Pipetting and mixing" operating mode, the mixing volume can be defined independent from the filling volume.
| Can the acustic feedback be turned off for the Xplorer? |
 |
Yes, the volume of the acustic feedback can be set to the levels 0-8 in the Options operating mode.
| How can accidental parameter changes be prevented? |
 |
"A complete run with volume, speed, etc. can be saved at the program level.
After exiting the program level, the run can no longer be changed just by pressing the keys. "
| "Various speeds can be selected with the Xplorer.
What speeds do the settings 1-8 represent?" |
 |
This is independent from the aspiration volume. Please contact the Application Hotline at www.support@eppendorf.com if you have any further questions.
| How long does it take the Research pro to aspirate 10 ml? |
 |
Based on a speed level between min. 2.6 S (Step 1) and max. 12 S (Step 8).
| Is the Xplorer UV-stable? |
 |
"The Xplorer is UV-stable.
Longer periods of irradiation can lead to very minimal material discoloration that does not have any effect on functionality."
| Does the technical data also apply to the Dispensing operating mode? |
 |
"The Xplorer technical data is only valid for pipetting. Conformity must be achieved for this operating mode.
For piston-stroke pipettes, there are no requirements for dispensing accuracy according to EN ISO 8655."
| Can the aspiration volume be limited? |
 |
Yes, a volume limit can be defined in the "Options" operating mode.
| "What charging possibilities are available for the Xplorer?" |
 |
"The Xplorer can be charged using the power supply included in the accessories or the optionally available charging stand or charging carousel.
One Xplorer can be charged with the charging stand and four with the charging carousel. A single-channel or multi-channel Xplorer can be attached to a charging shell."
| Can the Xplorer also be charged in Multipette charging stands? |
 |
"No, the Xplorer cannot be charged in the Multipette charging stand.
But the charging shells of the Xplorer charging stand can be exchanged. A charging shell for a Multipette stream/Xstream can be used instead of a charging shell for an Xplorer. "
| How long is the service life of the battery? |
 |
The li-ion battery features high energy density. Its usable service life is several years; but this is strongly dependent on usage and storage conditions.
| Can the battery be reordered? |
 |
Yes the battery can be individually ordered by customers as a spare part, or reordered.
| During gel loading, how can I prevent liquid from spraying out of the gel pouches during dispensing? |
 |
Due to the reduction in dispensing speed and additional vacuums of the Blow out, the sample can be accurately dispensed in the gel-slots. The enormous synchronization of the Xplorer motor also achieves very good results. In the operating mode "Pipetting and mixing P/M," the sample is automatically mixed with the preparation after dispensing. The mixing cycles and mixing volume can be individually defined for this.
| Can small volumes be mixed with each other during the preparation or liquids in the micro test plate? |
 |
In the operating mode "Pipetting and mixing P/M," the sample is automatically mixed with the preparation after dispensing. The mixing cycles and mixing volume can be individually defined for this.
| Can I precisely dispense liquids such as ethanol or glycerol with the Xplorer? |
 |
"On the Xplorer, the pipette can be adjusted to different liquids or geographic heights using 1, 2 or 3-point adjustment,
taking into account the corresponding density and associated scale results. The setting for ethanol 75 %25 or glycerol 50 %25 is completed using an internally determined factor that takes into account the density. "
| Can small volumes be mixed with each other during the preparation or liquids in the micro test plate? |
 |
In the operating mode "Pipetting and mixing P/M," the sample is automatically mixed with the preparation after dispensing. The mixing cycles and mixing volume can be individually defined for this.
| Can I precisely dispense liquids such as ethanol or glycerol with the Xplorer? |
 |
On the Xplorer, the pipette can be adjusted to different liquids or geographic heights using 1, 2 or 3-point adjustment,
taking into account the corresponding density and associated scale results. The setting for ethanol 75 %25 or glycerol 50 %25 is completed using an internally determined factor that takes into account the density.
|