Eppendorf Research plus adjustable multichannel pipette
Simply Superior Parallel Liquid Handling Capabilities
|
|
|
|
|
|
|
Save even more than 28%!!
POCDS can offer very substantial further discounts for bulk orders/ special pricing/ package deals on the full range of Eppendorf pipettes (Includes Eppendorf Research plus pipettes: Research Pack starter kits; Research plus single and multi-channel; Xplorer manual and electronic; Easypet pipette boys, Multipette dispensers, Varispenser bottle top dispensers; Stream and Xstream electronic dispensers etc
Please visit our Bulk Liquid Handling Deals page to make an enquiry
for special pricing/package deals/bulk pricing on these products
| overview |
features |
technical |
ordering |
consumables |
accessories |
downloads |
FAQs |
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ overview |
 | These are POCDS Time Critical Products - we are seriously committed to having these products in stock 24/7/365 for immediate shipping. If we are unable to immediately dispatch any of these items to you upon receiving your order we will airfreight the item from Germany at our expense to minimise the delay in getting the item to you. |
Eppendorf sets a new standard in pipetting. The ultra light multichannel Eppendorf Research plus pipette meets the highest needs in precision and accuracy – combined with ultimate ergonomics and increased flexibility.
It is a good feeling to know you are doing the right thing – to know you are working with the most advanced pipette in the world. A spring loaded tip cone, a secondary calibration option, an improved volume display – and all that in an ultra light, fully autoclavable pipette: That is the new Eppendorf Research plus pipette.
In Australia its an even better feeling to know that you are dealing with the strongest link in the supply chain - POCDScientific's sales consultants know this instrument inside out and can offer you the best deal in terms of price, supply, expertise and knowledge.
Ergonomics: The more strain you experience, the less energy you have. And because energy is a very precious and exhaustible resource, we try to use it as efficiently as possible. Thus the Eppendorf Research plus has been developed within the strict criteria of the Eppendorf PhysioCare Concept®.
PhysioCare Concept® stands for ultimate durability, intuitive operation and above all for perfect balance and minimal user exertion.
Flexibility: Your next experiment will need new pipetting schemes. Your new laboratory might have different sources of contamination. Your new pipette should offer all the flexibility you need. Calibrate your Research plus to your needs, autoclave the entire pipette or only the lower part. Choose among single channel, multi channel and fix-volume pipettes in different sizes.
Robustness: Durability was tested thoroughly and has met the highest quality requirements. Resistance to chemical, thermal and mechanical stress is now unchallenged!
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ features |
- Volume adjustment: Only a few turns to reach your desired volume
- Control button: Very low operating force, colour indicates pipette volume, positioned for perfect ergonomics
- Ejector: Very low operating force, positioned for perfect ergonomics
- Volume display: 4 digits, magnifying shape
- Calibration display & adjustment opening: Calibrate your pipette to a specific liquid and volume
- Eppendorf PerfectPiston™: Ultra light piston made of Fortron® (not in 2.5 µl, 10 µl, 5 ml and 10 ml pipettes)
- Quick connection clip: Remove lower part easily (not in 5 ml and 10 ml pipettes)
- Spring loaded tip cone: Improved ergonomics, tight fit to the tip (not in 5 ml and 10 ml pipettes)
- Channel indicator: – Use the pipette the same way round – all the time
- Remove individual channels: Gain flexibility for individual needs
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ technical |
| Volume range |
Volume |
Systematic error |
Random error |
| Operating button grey for pipette tips 20 μl |
| 0,5–10 μl |
0,5 μl |
±12,0% |
±0,06 μl |
±8,0% |
±0,04 μl |
| |
1 μl |
±8,0% |
±0,08 μl |
±5,0% |
±0,05 μl |
| |
5 μl |
±4,0% |
±0,2 μl |
±2,0% |
±0,1 μl |
| |
10 μl |
±2,0% |
±0,2 μl |
±1,0% |
±0,1 μl |
| |
| Operating button yellow for pipette tips 200 μl |
|
10–100 μl
|
10 μl |
±3,0% |
±0,3 μl |
±2,0% |
±0,2 μl |
| |
50 μl |
±1,0% |
±0,5 μl |
±0,8% |
±0,4 μl |
| |
100 μl |
±0,8% |
±0,8 μl |
±0,3% |
±0,3 μl |
| |
| Operating button orange for pipette tips 300 μl |
| 30–300 μl |
30 μl |
±3,0% |
±0,9 μl |
±1,0% |
±0,3 μl |
| |
150 μl |
±1,0% |
±1,5 μl |
±0,5% |
±0,75 μl |
| |
300 μl |
±0,6% |
±1,8 μl |
±0,3% |
±0,9 μl |
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ ordering |
Please note: | We have endeavoured to provide Australian catalogue numbers; however it would be prudent to verify any catalogue numbers taken straight from our site with POCD Scientific before using them to place an order.
We are seriously committed to having these product in stock 24/7/365 for immediate shipping. However we do need to acknowledge that spikes of demand can temporarily deplete our normally robust stock levels. If such a situation affects your order we will airfreight the item from Eppendorf at our expense to minimise the delay in getting the item to you. |
| Volume range |
Order number |
| 8-channel |
12-channel |
| Operating button grey for pipette tips 20 μl |
| 0,5–10 μl |
3122 000.019 |
3122 000.027 |
| Operating button yellow for pipette tips 200 μl |
| 10–100 μl |
3122 000.035 |
3122 000.043 |
| Operating button orange for pipette tips 300 μl |
| 30-300 μl |
3122 000.051 |
3122 000.060 |
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ accessories |
 The rotating pipette stand makes for an organized workplace. The new kind of attachment means that the pipette is no longer held at the bottom, ruling out potential contamination of a pipette by it being put on a stand.
All the older models of pipette can likewise be stored in the new pipette carousel.
In addition to the pipette carousel, there is a practical pipette holder for attachment to the wall. This means the pipette is always within reach and does not waste any valuable working space.
Dispensing is a routine, manual task for medical, molecular biology and pharmaceutical applications. This manual offers an overview of the current dispensing techniques and the main application fields in scientific and industrial laboratories. Today’s laboratories require extremely precise pipetting/dispensing processes down to the microliter range, and there are many products available for the transport and preparation of liquid samples.
Now in its third edition, this manual addresses the physical fundamentals and utilization limits of the current techniques. Quality management in terms of international standards is also covered.
Author: Kornelia Ewald, Eppendorf AG
Liquid Handling: Laboratory Practice, 3rd edition:
Ewald, Kornelia; Schirm, Peter; Jahns, Axel.
Landsberg: verlag moderne industrie, 2005
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ consumables |
Tip Tub / Reagent Reservoir
| Tip Tub / Reagent Reservoir |
 |
Volume |
| 60ml filling capacity |
| Quantity |
| pack 10 pcs, with lid |
| Ordering no. |
| 0030 058 607 |
|
Tips
| epTIPS |
Purity |
Packaging |
Ordering no. |
|
| 0.1-10 µL, 34 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.811 |
| Reloads |
|
10 trays of 96 tips = 960 tips** |
0030 073.363 |
|
Reloads
|
PCR-clean |
10 trays of 96 tips = 960 tips** |
0030 073.746 |
|
Box
|
|
1 reusable box incl. 96 tips |
0030 073.002 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.207 |
|
| 0.1-20 µL, 40 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.838 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.380 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.762 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.029 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.223 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.019 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.005 |
|
| 0.5-20 µL, 46 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.854 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.401 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.789 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.045 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.240 |
|
| 2-200 µL, 53 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.870 |
| Reloads |
|
10 trays of 96 tips = 960 tips** |
0030 073.428 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips** |
0030 073.800 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.061 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.266 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.035 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.021 |
|
| 20-300 µL, 55 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.897 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.444 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.827 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.088 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.282 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.048 |
|
| 50-1,000 µL,71 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.919 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.460 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.843 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.100 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.304 |
| Singles |
Biopur |
100 tips, individually wrapped |
0030 010.051 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.064 |
|
| 50-1,250 µL, 76 mm |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.935 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.487 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.860 |
| Box |
|
1 reusable box incl. 96 tips |
0030 073.126 |
| Set |
|
1 reusable box incl. 5 trays of 96 tips |
0030 073.320 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.080 |
|
| 50-1,250 µL, 103 mm (eLongated) |
 |
| Standard |
|
2 bags of 500 tips = 1,000 tips |
0030 000.730 |
| Reloads |
|
10 trays of 96 tips = 960 tips |
0030 073.606 |
| Reloads |
PCR-clean |
10 trays of 96 tips = 960 tips |
0030 073.614 |
| Racks |
|
5 racks of 96 tips = 480 tips |
0030 075.129 |
| Racks |
PCR-clean |
5 racks of 96 tips = 480 tips |
0030 075.129 |
| Racks |
Biopur |
5 racks of 96 tips = 480 tips |
0030 075.129 |
|
| 500-2,500 µL, 115 mm |
 |
| Standard |
|
5 bags of 100 tips = 500 tips |
0030 000.951 |
| Reloads |
|
10 trays of 48 tips = 480 tips |
0030 073.509 |
| Reloads |
PCR-clean |
10 trays of 48 tips = 480 tips |
0030 073.886 |
| Box |
|
1 reusable box incl. 48 tips |
0030 073.142 |
| Set |
|
1 reusable box incl. 5 trays of 48 tips |
0030 073.347 |
| Racks |
Biopur |
5 racks of 48 tips = 240 tips |
0030 075.102 |
|
| 100-5,000 µL, 120 mm |
 |
| Standard |
|
5 bags of 100 tips = 500 tips |
0030 000.978 |
| Box |
|
1 reusable box incl. 24 tips |
0030 073.169 |
|
| 1-10 ml, 165 mm |
 |
| Standard |
|
2 bags of 100 tips = 200 tips |
0030 000.765 |
| Racks |
Biopur |
5 racks of 24 tips = 120 tips |
0030 075.145 |
|
| 1-10 ml L, 243 mm |
 |
| Standard |
|
2 bags of 100 tips = 200 tips |
0030 000.781 |
* All pipette tips meet the "Eppendorf Quality" purity standard.
** Packed in the form of a stack. All non-marked epTIPS Reloads are packed dual-sided |
|
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ downloads |
| Document |
Size |
download |
| Eppendorf Research® plus Operating Manual |
2 MB |
 |
| Eppendorf SOP - Standard Operating Procedure for pipettes |
4 MB |
 |
| Adjustment Factory |
704 KB |
 |
| Chemical Resistance |
445 KB |
 |
| Pipette holder |
90 KB |
 |
These are PDF files, to obtain a free Adobe PDF reader:  |
 POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus Multichannel pipettes ~ FAQs |
| What are the main features of the Eppendorf Research plus? |
 |
Main features are: very low weight, spring loaded tip cone (exception: 5 mL and 10 mL Research plus) which leads to an easy and homogeneous tip attachment even when working with a multi-channel pipette and thus, to very low operation forces and finally, an easy adjustment by the user. In addition, the Research plus shows a very good accuracy and precision, is fully autoclavable at 121 °C, 1 bar for 20 min, features excellent chemical resistance and has an adjustment display offering optical control if an adjustment of the pipette has been performed.
| In which sizes is the Eppendorf Research plus available? |
 |
The Research plus is available as fixed-volume pipettes, adjustable pipettes and as 8-channel and 12-channel pipettes (with adjustable volumes).
Besides the present volume range of our Research Pipettes, the Research plus is offered in the following additional sizes:
Fixed-volume pipettes: 10 µL pipette for pipette tips 0.1-20 µL, 20 µL pipette for pipette tips 0.5-20 µL L and 200 µL pipette for pipette tips 2-200 µL.
Adjustable pipettes: 2-20 µL pipette for pipette tips 0.5-20 µL L, 30-300 µL pipette for pipette tips 20-300 µL.
These new models feature an even higher precision due to a smaller air-cushion in the pipette tip compared to tips with higher volumes.
For detailed information on the different model sizes, please check the ordering information Research plus
(http://www.eppendorf.de/int/index.php?sitemap=2.1&pb=49f30398a74e856f&action=products&contentid=1&catalognode=28831&page=15)
| Is the Research plus resistent to concentrated acids? |
 |
Yes. Please notice that the usage of aggressive chemicals over a longer period of time will reduce the life span of the pipette.
| Is a gravimetric test necessary after resetting the adjustment display to "0"? |
 |
From a technical standpoint, no. Only for certified laboratories, a gravimetric test might be necessary for documentation purposes.
| Is accuracy (systematic error) affected if the Research plus multi-channel pipette is not fully attached with tips or if individual channels of the pipette are removed? |
 |
It does not affect the accuracy of pipetting if the Research plus multi-channel pipette is not fully attached with tips or if individual channels are removed.
| Is the Research plus compatible with hydrofluoric acid? |
 |
Yes. Please notice that the usage of aggressive chemicals like hydrofluoric acid over a longer period of time will reduce the life span of the pipette.
| Is the Research plus compatible with hydrochloric acid? |
 |
Yes. Please notice that the usage of aggressive chemicals like hydrochloric acid over a longer period of time will reduce the life span of the pipette.
| How many overnight cycles or total hours of UV irradiation can the Research plus withstand before any discoloration or change of the material will be visible? |
 |
We tested UV radiation over a time period of 165 hours of continuos radiation and under very intense conditions. There were no visible discoloration or changes in the material.
| Is it necessary to re-grease the piston of the pipette after autoclaving? |
 |
No, it is not necessary.
| Can the Research plus be autoclaved if the locking ring is installed to deactivate the spring loading? |
 |
Yes. The locking ring is made of PPS (polyphenylene sulfide) and therefore autoclavable (121 °C, 1 bar, 20 min).
| Is the Research plus compatible with sodium hydroxide (>10 %)? |
 |
Yes.
| Is the Research plus compatible with 65 % nitric acid? |
 |
Yes. Please notice that the usage of aggressive chemicals like nitric acid over a longer period of time will reduce the life span of the pipette.
| When do I have to lubricate the piston of a Research plus pipette? |
 |
If the pipette is contaminated with a liquid which enters the pipette's internal parts, the user will have to disassemble the lower part, clean the piston and the nose cone . In this case, the grease is removed from the piston and the piston needs to be regreased before reassembly. To do so, we recommend to use our pipette grease (1 g, order no. 0013 063.010).
| Do I need to disassemble the Research plus before autoclaving? |
 |
No. It can be autoclaved in one piece (121 °C, 1 bar, 20 min).
| What are the settings of the Research plus pipette for liquids of different viscosities or specific densities? |
 |
The user manual of the Research plus mentions specific settings for some volumes of the most common liquid classes. These values are for orientation only as the systematic and random error are affected by the mode of operation, the tip used and other factors like the temperature. It is essential to check these data according to your own work method.
| If my Research plus deviates significantly from the limit values, how can I find out whether this is a measuring error or a problem with the pipette? |
 |
We recommend to dismantle the pipette into its individual parts (see operating instructions) and to clean these. Afterwards calibrate your pipette following the instructions given in our SOP. Values which deviate significantly from the limit value should now no longer occur. However, if there is no contamination, please contact your local Eppendorf style partner for service of your pipette.
| Will water vapor enter into the pipette while it is being autoclaved, causing water vapor to bead up on the inside of the numerical volume setting display? |
 |
Vapor will penetrate the inside of the pipette during autoclaving but this will not damage anything. We tested our pipettes with 175 autoclaving cycles (121 °C, 1 bar, 20 min). The number of respective tests chosen corresponds to an average of 5 years of use.
| Can the Research plus be washed with sodium hypochlorite for disinfection? |
 |
Yes. The outside of the tip cone and ejector sleeve can be wiped with 4 % sodium hypochlorite solution. After the exposure time of the sodium hypochlorite solution has elapsed, remove thoroughly with demineralized water.
| In part 3 of the operating manual of the Research plus you recommend to adjust the volume setting from a higher value to a lower value. If required, the user should turn the value beyond the required valued and than back again. What is the reason for such a recommendation? |
 |
For technical reasons, the results are generally more precise when a volume setting is carried out from a higher down to a lower value. This is valid for all manual pipettes.
| Are any O-rings or any other type of rubber gaskets present on the insides of the single-channel Research plus? |
 |
There are no single O-rings or other separate parts inside. All parts are integrated into the piston. Only the lower parts of the multi-channel Research plus pipettes are equipped with O-rings.
| How should contaminations on the outside of the Research plus be removed? |
 |
We recommend to wet a cloth with water or 70% isopropanol and to remove the contamination.
| How should disinfection of the Research plus be performed? |
 |
Wipe off the outer surface with disinfectant, DNA/RNA decontamination agent or 70 % isopropanol. Alternatively wipe the outside of the tip cone and ejector sleeve with 4 % sodium hypochlorite solution. After the exposure time of the sodium hypochlorite solution has elapsed, remove thoroughly with demineralized water. Alternatively the Research plus may be temporarily subjected to UV light under a sterile bench.Here we recommend the use of a Hg-lamp, 254 nm, 30 W. The distance between lamp and pipette should be approx. 60 cm.
| What information is available through the adjustment display of the Research plus? |
 |
As each Research plus pipette has been calibrated and adjusted before delivery, the adjustment display shows "0". As soon as the adjustment is changed by the user, the reading on the display will be changed, too. Therefore, the adjustment display provides optical control if a pipette has been adjusted to another volume.
| What do I have to observe regarding maintenance and cleaning of the Research plus? |
 |
The Research plus pipettes are easy to clean. Only the lower part should be cleaned on a regular basis, in accordance with the frequency of use. The lower part of the single-channel and multi-channel Research plus pipettes can be removed easily as described in the operating manual of the Research plus or in our Application Note 198. (http://www.eppendorf.de/int/index.php?sitemap=4.1&pb=f69dc5897412b7d4&action=support&contentid=1&catalognode=67026&productpage=7)
| When should the spring loading of the single-channel Research plus pipettes be deactivated? |
 |
For dispensing tasks in which a pipette tip is used over a long time or is slightly bended, it can be helpful to deactivate the spring loading of the tip cone by installing the locking ring. This can also be helpful for pipette tips which are not designed for the Eppendorf pipette cones.
|