Eppendorf Australian Distributor - POCD Scientific - click for home pageEppendorf Australian Distributor - POCD Scientific header banner
site search heading
search

POCD Scientific Specials
  • EOFY Specials
  • Microcentrifuge Bonus
  • 58XX Centrifuge
           Free goods & Discount
  • PCR Solutions Bonuses
  • Eppendorf Advantage
  • 2013 Trade in/up offers

  • New Products at POCDS
  • Feather Microtome blades
          in a disposable dispenser
  • Xplorer Plus Electronic
         Automatic Pipette
  • Tharmac Cellspin I
  • Tharmac Cellspin II
  • Tharmac Cellstain 15
  • Tharmac Cellstain 7
  • Tharmac Cellstain 6
  • Tharmac Consumables
  • Centrifuge 5427R
  • AnD Scientific balances
  • qTower Rapid qPCR
  • Rockers/shakers/mixers
  • Buhler Mixers
  • PCR: Mastercycler Nexus
  • VIAFLO 384 tip semi-
         automated plate pipetting
  • VIAFLO 96 tip semi-
         automated plate pipetting
  • Voyager variable-
         spacing pipette
  • Water Baths
  • Bead Baths
  • Deepwell plates
  • Polypropylene Microplate
  • Real-time PCR plates

  • Best Sellers: Quick links to POCD Scientific most sought-after products
  • Centrifugation
  • Combitips Advanced
  • Micro centrifuge
  • Compact Benchtop
  • Multi-purpose Centrifuge
  • Pipette Starter Pack
  • Eppendorf pipettes
  • Multichannel  Pipette
  • Electronic  Pipette
  • Multipette repeating
  • PCR tubes
  • Microcentrifuge tubes


  • Eppendorf Liquid Handling Pipettes logo
  • Centrifugation
  • Pipettes, Dispensers
  • Consumables & more
  • Tips, Tubes and Plates
  • Find the Right Tube!
  • PCR
  • Temp control & mixing
  • Spectrophotometer
  • BioSpectrometer
  • MicroManipulation
  • Technical Service
  • Electroporation
  • Vacuum Concentration



  • spacer-force 150px wide
    spacer force 10px, 750 deep wide spacer-force 840px wide
    Eppendorf Research<sup>®</sup> plus adjustable pipette is a Best Selling item at POCD Scientific Eppendorf Research® plus adjustable pipette

    Simply Superior Liquid Handling Capabilities

    Elegible for our Exciting Upgrade offer - click to read more

    Save even more than 28%!!

    POCDS can offer very substantial further discounts for bulk orders/ special pricing/ package deals on the full range of Eppendorf pipettes (Includes Eppendorf Research plus pipettes: Research Pack starter kits; Research plus single and multi-channel; Xplorer manual and electronic; Easypet pipette boys, Multipette dispensers, Varispenser bottle top dispensers; Stream and Xstream electronic dispensers etc

    Please visit our Bulk Liquid Handling Deals page to make an enquiry for special pricing/package deals/bulk pricing on these products

    overview features technical ordering consumables accessories downloads FAQ answers videos

    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ overview

    this is a critical productThese are POCDS Time Critical Products - we are seriously committed to having these products in stock 24/7/365 for immediate shipping. If we are unable to immediately dispatch any of these items to you upon receiving your order we will airfreight the item from Germany at our expense to minimise the delay in getting the item to you.


    Eppendorf Eppendorf Research Plus adjustable pipette Red dot design award  winner 2009 Eppendorf Research® plus pipette (adjustable)

    Eppendorf sets a new standard in pipetting. The ultra light adjustable Eppendorf Research plus pipette meets the highest needs in precision and accuracy – combined with ultimate ergonomics and increased flexibility.

    It is a good feeling to know you are doing the right thing – to know you are working with the most advanced pipette in the world. A spring loaded tip cone, a secondary calibration option, an improved volume display – and all that in an ultra light, fully autoclavable pipette: That is the new Eppendorf Research plus pipette.

    In Australia its an even better feeling to know that you are dealing with the strongest link in the supply chain - POCDScientific's sales consultants know this instrument inside out and can offer you the best deal in terms of price, supply, expertise and knowledge.

    Ergonomics: The more strain you experience, the less energy you have. And because energy is a very precious and exhaustible resource, we try to use it as efficiently as possible. Thus the Eppendorf Research plus has been developed within the strict criteria of the Eppendorf PhysioCare Concept®. PhysioCare Concept® stands for ultimate durability, intuitive operation and above all for perfect balance and minimal user exertion.

    Flexibility: Your next experiment will need new pipetting schemes. Your new laboratory might have different sources of contamination. Your new pipette should offer all the flexibility you need. Calibrate your Research plus to your needs, autoclave the entire pipette or only the lower part. Choose among single channel, multi channel and fix-volume pipettes in different sizes.

    Robustness: Durability was tested thoroughly and has met the highest quality requirements. Resistance to chemical, thermal and mechanical stress is now unchallenged!

    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ features



    Eppendorf Eppendorf Research Plus adjustable pipette Red dot design award  winner 2009
    • Volume adjustment: Only a few turns to reach your desired volume
    • Control button: Very low operating force, colour indicates pipette volume, positioned for perfect ergonomics
    • Ejector: Very low operating force, positioned for perfect ergonomics
    • Volume display: 4 digits, magnifying shape
    • Calibration display & adjustment opening: Calibrate your pipette to a specific liquid and volume
    • Eppendorf PerfectPiston™: Ultra light piston made of Fortron® (not in 2.5 µl, 10 µl, 5 ml and 10 ml pipettes)
    • Quick connection clip: Remove lower part easily (not in 5 ml and 10 ml pipettes)
    • Spring loaded tip cone: Improved ergonomics, tight fit to the tip (not in 5 ml and 10 ml pipettes)


    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ technical



    Volume range Volume Systematic error Random error
    Operating button anthracite for pipette tips 10 μl
    0.1–2.5 μl 0.1 μl ±48.0% ±0.048 μl ±12.0% ±0.012 μl
    0.25 μl ±12.0% ±0.03 μl ±6.0% ±0.015 μl
    1.25 μl ±2.5% ±0.031 μl ±1.5% ±0.019 μl
    2.5 μl ±1.4% ±0.035 μl ±0.7% ±0.018 μl
    Operating button grey for pipette tips 20 μl
    0.5 - 10 μl 0.5 μl ±8.0% ±0.04 μl ±5.0% ±0.025 μl
    1 μl ±2.5% ±0.025 μl ±1.8% ±0.018 μl
    5 μl ±1.5% ±0.075 μl ±0.8% ±0.04 μl
    10 μl ±1.0% ±0.1 μl ±0.4% ±0.04 μl
    Operating button light grey for pipette tips 20 μl L
    2–20 μl 2 μl ±5.0% ±0.1 μl ±1.5% ±0.03 μl
    10 μl ±1.2% ±0.12 μl ±0.6% ±0.06 μl
    20 μl ±1.0% ±0.2 μl ±0.3% ±0.06 μl
    Operating button yellow for pipette tips 200 μl
    2–20 μl 2 μl ±5.0% ±0.1 μl ±1.5% ±0.03 μl
    10 μl ±1.2% ±0.12 μl ±0.6% ±0.06 μl
    20 μl ±1.0% ±0.2 μl ±0.3% ±0.06 μl
    10–100 μl 10 μl ±3.0% ±0.3 μl ±1.0% ±0.1 μl
    50 μl ±1.0% ±0.5 μl ±0.3% ±0.15 μl
    100 μl ±0.8% ±0.8 μl ±0.2% ±0.2 μl
    20–200 μl 20 μl ±2.5% ±0.5 μl ±0.7% ±0.14 μl
    100 μl ±1.0% ±1.0 μl ±0.3% ±0.3 μl
    200 μl ±0.6% ±1.2 μl ±0.2% ±0.4 μl
    Operating button orange for pipette tips 300 μl
    30–300 μl 30 μl ±2.5% ±0.75 μl ±0.7% ±0.21 μl
    150 μl ±1.0% ±1.5 μl ±0.3% ±0.45 μl
    300 μl ±0.6% ±1.8 μl ±0.2% ±0.6 μl
    Operating button blue for pipette tips 1000 μl
    100–1.000 μl 100 μl ±3.0% ±3.0 μl ±0.6% ±0.6 μl
    500 μl ±1.0% ±5.0 μl ±0.2% ±1.0 μl
    1.000 μl ±0.6% ±6.0 μl ±0.2% ±2.0 μl
    Operating button violet for pipette tips 5 ml
    0,5–5 ml 0.5 ml ±2.4% ±0.012 ml ±0.6% ±0.003 ml
    2.5 ml ±1.2% ±0.03 ml ±0.25% ±0.006 ml
    5 ml ±0.6% ±0.03 ml ±0.15% ±0.008 ml
    Operating button turpoise for pipette tips 10 ml
    1–10 ml 1 ml ±3.0% ±0.03 ml ±0.6% ±0.006 ml
    5 ml ±0.8% ±0.04 ml ±0.2% ±0.01 ml
    10 ml ±0.6% ±0.06 ml ±0.15% ±0.015 ml


    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ accessories



    Eppendorf rotating pipette stand The rotating pipette stand makes for an organized workplace. The new kind of attachment means that the pipette is no longer held at the bottom, ruling out potential contamination of a pipette by it being put on a stand.

    All the older models of pipette can likewise be stored in the new pipette carousel.

    In addition to the pipette carousel, there is a practical pipette holder for attachment to the wall. This means the pipette is always within reach and does not waste any valuable working space.



    Eppendorf liquid handling manual

    Dispensing is a routine, manual task for medical, molecular biology and pharmaceutical applications. This manual offers an overview of the current dispensing techniques and the main application fields in scientific and industrial laboratories. Today’s laboratories require extremely precise pipetting/dispensing processes down to the microliter range, and there are many products available for the transport and preparation of liquid samples. Now in its third edition, this manual addresses the physical fundamentals and utilization limits of the current techniques. Quality management in terms of international standards is also covered.

    Author: Kornelia Ewald, Eppendorf AG
    Liquid Handling: Laboratory Practice, 3rd edition:
    Ewald, Kornelia; Schirm, Peter; Jahns, Axel.
    Landsberg: verlag moderne industrie, 2005



    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ ordering

    Please
    note:
    We have endeavoured to provide Australian catalogue numbers; however it would be prudent to verify any catalogue numbers taken straight from our site with POCD Scientific before using them to place an order.

    We are seriously committed to having these product in stock 24/7/365 for immediate shipping. However we do need to acknowledge that spikes of demand can temporarily deplete our normally robust stock levels. If such a situation affects your order we will airfreight the item from Eppendorf at our expense to minimise the delay in getting the item to you.


    Eppendorf Eppendorf Research Plus adjustable pipette
    Article Order no.
    Operating button anthrazite for pipette tips 10 μl
    0.1-2.5 µl 3120 000.011
    Operating button grey for pipette tips 20 μl
    0.5-10 µl 3120 000.020
    Operating button light grey for pipette tips 20 μl L
    2–20 μl 3120 000.097
    Operating button yellow for pipette tips 200 μl
    2.0-20 µl 3120 000.038
    10-100 µl 3120 000.046
    20-200 µl 3120 000.054
    Operating button orange for pipette tips 300 μl
    30–300 μl 3120 000.100
    Operating button blue for pipette tips 1000 μl
    100-1,000 µl 3120 000.062
    Operating button violet for pipette tips 5 ml
    0.5–5 ml 3120 000.070
    Operating button turpoise for pipette tips 10 ml
    1-10 ml 3120 000.089



    Eppendorf Pipettes Research plus 3-pack with tips             visit Starter pack page


    Article Order No. Eppendorf Pipettes  Research plus 3-pack with tips
    Eppendorf Research® plus
    Starter Pack, Option 1
    (0.5–10 μL, 10–100 μL, 100–1mL)
    3120 000.909
    Eppendorf Research® plus
    Starter Pack, Option 2
    (2–20 μL, 20–200 μL, 100–1mL)
    3120 000.917
    Eppendorf Research® plus
    Starter Pack, Option 3
    (0.1–1 mL, 0.5–5 mL, 1–10 mL)
    3120 000.925


    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ consumables



    epTIPS Purity Packaging Ordering no.
     
    0.1-10 µL, 34 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.811
    Reloads   10 trays of 96 tips = 960 tips** >0030 073.363
    Reloads PCR-clean 10 trays of 96 tips = 960 tips** >0030 073.746
    Box   1 reusable box incl. 96 tips >0030 073.002
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.207
     
    0.1-20 µL, 40 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.838
    Reloads   10 trays of 96 tips = 960 tips >0030 073.380
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.762
    Box   1 reusable box incl. 96 tips >0030 073.029
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.223
    Singles Biopur 100 tips, individually wrapped >0030 010.019
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.005
     
    0.5-20 µL, 46 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.854
    Reloads   10 trays of 96 tips = 960 tips >0030 073.401
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.789
    Box   1 reusable box incl. 96 tips >0030 073.045
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.240
     
    2-200 µL, 53 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.870
    Reloads   10 trays of 96 tips = 960 tips** >0030 073.428
    Reloads PCR-clean 10 trays of 96 tips = 960 tips** >0030 073.800
    Box   1 reusable box incl. 96 tips >0030 073.061
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.266
    Singles Biopur 100 tips, individually wrapped >0030 010.035
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.021
     
    20-300 µL, 55 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.897
    Reloads   10 trays of 96 tips = 960 tips >0030 073.444
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.827
    Box   1 reusable box incl. 96 tips >0030 073.088
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.282
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.048
     
    50-1,000 µL,71 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.919
    Reloads   10 trays of 96 tips = 960 tips >0030 073.460
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.843
    Box   1 reusable box incl. 96 tips >0030 073.100
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.304
    Singles Biopur 100 tips, individually wrapped >0030 010.051
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.064
     
    50-1,250 µL, 76 mm
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.935
    Reloads   10 trays of 96 tips = 960 tips >0030 073.487
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.860
    Box   1 reusable box incl. 96 tips >0030 073.126
    Set   1 reusable box incl. 5 trays of 96 tips >0030 073.320
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.080
     
    50-1,250 µL, 103 mm (eLongated)
    Standard   2 bags of 500 tips = 1,000 tips >0030 000.730
    Reloads   10 trays of 96 tips = 960 tips >0030 073.606
    Reloads PCR-clean 10 trays of 96 tips = 960 tips >0030 073.614
    Racks   5 racks of 96 tips = 480 tips >0030 075.129
    Racks PCR-clean 5 racks of 96 tips = 480 tips >0030 075.129
    Racks Biopur 5 racks of 96 tips = 480 tips >0030 075.129
     
    500-2,500 µL, 115 mm
    Standard   5 bags of 100 tips = 500 tips >0030 000.951
    Reloads   10 trays of 48 tips = 480 tips >0030 073.509
    Reloads PCR-clean 10 trays of 48 tips = 480 tips >0030 073.886
    Box   1 reusable box incl. 48 tips >0030 073.142
    Set   1 reusable box incl. 5 trays of 48 tips >0030 073.347
    Racks Biopur 5 racks of 48 tips = 240 tips >0030 075.102
     
    100-5,000 µL, 120 mm
    Standard   5 bags of 100 tips = 500 tips >0030 000.978
    Box   1 reusable box incl. 24 tips >0030 073.169
     
    1-10 ml, 165 mm
    Standard   2 bags of 100 tips = 200 tips >0030 000.765
    Racks Biopur 5 racks of 24 tips = 120 tips >0030 075.145
     
    1-10 ml L, 243 mm
    Standard   2 bags of 100 tips = 200 tips >0030 000.781

    * All pipette tips meet the "Eppendorf Quality" purity standard.
    ** Packed in the form of a stack. All non-marked epTIPS Reloads are packed dual-sided

    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ downloads



    Document Size download
    Eppendorf Research® plus Operating Manual 2 MB click to download
    The Eppendorf Research® plus pipette – lightweight, reliable and ergonomic (Eppendorf Application Note 197) 819 KB click to download
    The Eppendorf Research® plus pipette – fully autoclavable, easy adjustment, quick and simple maintenance (Eppendorf Application Note 198) 887 KB click to download
    Fundamentals of dispensing (Eppendorf Userguide 19) 1 MB click to download
    Impact of pipetting techniques on precision and accuracy (Eppendorf Userguide 20) 478 KB click to download
    Physical influences on the dispensed volume with air-cushion pipettes (Eppendorf Userguide 21) 238 KB click to download
    Cleaning and inspection of pipettes (Eppendorf Userguide 24) 200 KB click to download
    Calibration and adjustment of dispensing systems in the laboratory (Eppendorf Userguide 25) 267 KB click to download
    Eppendorf SOP - Standard Operating Procedure for pipettes 4 MB click to download
    Adjustment Factory 704 KB click to download
    Chemical Resistance 445 KB click to download
    Pipette holder 90 KB click to download
    These are PDF files, to obtain a free Adobe PDF reader:     click to obtain a free Adobe PDF reader

    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ FAQs



    What are the main features of the Eppendorf Research plus?

    In which sizes is the Eppendorf Research plus available?

    Is the Research plus resistent to concentrated acids?

    Is a gravimetric test necessary after resetting the adjustment display to "0"?

    Is accuracy (systematic error) affected if the Research plus multi-channel pipette is not fully attached with tips or if individual channels of the pipette are removed?

    Is the Research plus compatible with hydrofluoric acid?

    Is the Research plus compatible with hydrochloric acid?

    How many overnight cycles or total hours of UV irradiation can the Research plus withstand before any discoloration or change of the material will be visible?

    Is it necessary to re-grease the piston of the pipette after autoclaving?

    Can the Research plus be autoclaved if the locking ring is installed to deactivate the spring loading?

    Is the Research plus compatible with sodium hydroxide (>10 %)?

    Is the Research plus compatible with 65 % nitric acid?

    When do I have to lubricate the piston of a Research plus pipette?

    Do I need to disassemble the Research plus before autoclaving?

    What are the settings of the Research plus pipette for liquids of different viscosities or specific densities?

    If my Research plus deviates significantly from the limit values, how can I find out whether this is a measuring error or a problem with the pipette?

    Will water vapor enter into the pipette while it is being autoclaved, causing water vapor to bead up on the inside of the numerical volume setting display?

    Can the Research plus be washed with sodium hypochlorite for disinfection?

    In part 3 of the operating manual of the Research plus you recommend to adjust the volume setting from a higher value to a lower value. If required, the user should turn the value beyond the required valued and than back again. What is the reason for such a recommendation?

    Are any O-rings or any other type of rubber gaskets present on the insides of the single-channel Research plus?

    How should contaminations on the outside of the Research plus be removed?

    How should disinfection of the Research plus be performed?

    What information is available through the adjustment display of the Research plus?

    What do I have to observe regarding maintenance and cleaning of the Research plus?

    When should the spring loading of the single-channel Research plus pipettes be deactivated?

    What are the main features of the Eppendorf Research plus? Back to top
    Main features are: very low weight, spring loaded tip cone (exception: 5 mL and 10 mL Research plus) which leads to an easy and homogeneous tip attachment even when working with a multi-channel pipette and thus, to very low operation forces and finally, an easy adjustment by the user. In addition, the Research plus shows a very good accuracy and precision, is fully autoclavable at 121 °C, 1 bar for 20 min, features excellent chemical resistance and has an adjustment display offering optical control if an adjustment of the pipette has been performed.
    In which sizes is the Eppendorf Research plus available? Back to top
    The Research plus is available as fixed-volume pipettes, adjustable pipettes and as 8-channel and 12-channel pipettes (with adjustable volumes). Besides the present volume range of our Research Pipettes, the Research plus is offered in the following additional sizes: Fixed-volume pipettes: 10 µL pipette for pipette tips 0.1-20 µL, 20 µL pipette for pipette tips 0.5-20 µL L and 200 µL pipette for pipette tips 2-200 µL. Adjustable pipettes: 2-20 µL pipette for pipette tips 0.5-20 µL L, 30-300 µL pipette for pipette tips 20-300 µL. These new models feature an even higher precision due to a smaller air-cushion in the pipette tip compared to tips with higher volumes. For detailed information on the different model sizes, please check the ordering information Research plus (http://www.eppendorf.de/int/index.php?sitemap=2.1&pb=49f30398a74e856f&action=products&contentid=1&catalognode=28831&page=15)
    Is the Research plus resistent to concentrated acids? Back to top
    Yes. Please notice that the usage of aggressive chemicals over a longer period of time will reduce the life span of the pipette.
    Is a gravimetric test necessary after resetting the adjustment display to "0"? Back to top
    From a technical standpoint, no. Only for certified laboratories, a gravimetric test might be necessary for documentation purposes.
    Is accuracy (systematic error) affected if the Research plus multi-channel pipette is not fully attached with tips or if individual channels of the pipette are removed? Back to top
    It does not affect the accuracy of pipetting if the Research plus multi-channel pipette is not fully attached with tips or if individual channels are removed.
    Is the Research plus compatible with hydrofluoric acid? Back to top
    Yes. Please notice that the usage of aggressive chemicals like hydrofluoric acid over a longer period of time will reduce the life span of the pipette.
    Is the Research plus compatible with hydrochloric acid? Back to top
    Yes. Please notice that the usage of aggressive chemicals like hydrochloric acid over a longer period of time will reduce the life span of the pipette.
    How many overnight cycles or total hours of UV irradiation can the Research plus withstand before any discoloration or change of the material will be visible? Back to top
    We tested UV radiation over a time period of 165 hours of continuos radiation and under very intense conditions. There were no visible discoloration or changes in the material.
    Is it necessary to re-grease the piston of the pipette after autoclaving? Back to top
    No, it is not necessary.
    Can the Research plus be autoclaved if the locking ring is installed to deactivate the spring loading? Back to top
    Yes. The locking ring is made of PPS (polyphenylene sulfide) and therefore autoclavable (121 °C, 1 bar, 20 min).
    Is the Research plus compatible with sodium hydroxide (>10 %)? Back to top
    Yes.
    Is the Research plus compatible with 65 % nitric acid? Back to top
    Yes. Please notice that the usage of aggressive chemicals like nitric acid over a longer period of time will reduce the life span of the pipette.
    When do I have to lubricate the piston of a Research plus pipette? Back to top
    If the pipette is contaminated with a liquid which enters the pipette's internal parts, the user will have to disassemble the lower part, clean the piston and the nose cone . In this case, the grease is removed from the piston and the piston needs to be regreased before reassembly. To do so, we recommend to use our pipette grease (1 g, order no. 0013 063.010).
    Do I need to disassemble the Research plus before autoclaving? Back to top
    No. It can be autoclaved in one piece (121 °C, 1 bar, 20 min).
    What are the settings of the Research plus pipette for liquids of different viscosities or specific densities? Back to top
    The user manual of the Research plus mentions specific settings for some volumes of the most common liquid classes. These values are for orientation only as the systematic and random error are affected by the mode of operation, the tip used and other factors like the temperature. It is essential to check these data according to your own work method.
    If my Research plus deviates significantly from the limit values, how can I find out whether this is a measuring error or a problem with the pipette? Back to top
    We recommend to dismantle the pipette into its individual parts (see operating instructions) and to clean these. Afterwards calibrate your pipette following the instructions given in our SOP. Values which deviate significantly from the limit value should now no longer occur. However, if there is no contamination, please contact your local eppendorf partner for service of your pipette.
    Will water vapor enter into the pipette while it is being autoclaved, causing water vapor to bead up on the inside of the numerical volume setting display? Back to top
    Vapor will penetrate the inside of the pipette during autoclaving but this will not damage anything. We tested our pipettes with 175 autoclaving cycles (121 °C, 1 bar, 20 min). The number of respective tests chosen corresponds to an average of 5 years of use.
    Can the Research plus be washed with sodium hypochlorite for disinfection? Back to top
    Yes. The outside of the tip cone and ejector sleeve can be wiped with 4 % sodium hypochlorite solution. After the exposure time of the sodium hypochlorite solution has elapsed, remove thoroughly with demineralized water.
    In part 3 of the operating manual of the Research plus you recommend to adjust the volume setting from a higher value to a lower value. If required, the user should turn the value beyond the required valued and than back again. What is the reason for such a recommendation? Back to top
    For technical reasons, the results are generally more precise when a volume setting is carried out from a higher down to a lower value. This is valid for all manual pipettes.
    Are any O-rings or any other type of rubber gaskets present on the insides of the single-channel Research plus? Back to top
    There are no single O-rings or other separate parts inside. All parts are integrated into the piston. Only the lower parts of the multi-channel Research plus pipettes are equipped with O-rings.
    How should contaminations on the outside of the Research plus be removed? Back to top
    We recommend to wet a cloth with water or 70% isopropanol and to remove the contamination.
    How should disinfection of the Research plus be performed? Back to top
    Wipe off the outer surface with disinfectant, DNA/RNA decontamination agent or 70 % isopropanol. Alternatively wipe the outside of the tip cone and ejector sleeve with 4 % sodium hypochlorite solution. After the exposure time of the sodium hypochlorite solution has elapsed, remove thoroughly with demineralized water. Alternatively the Research plus may be temporarily subjected to UV light under a sterile bench.Here we recommend the use of a Hg-lamp, 254 nm, 30 W. The distance between lamp and pipette should be approx. 60 cm.
    What information is available through the adjustment display of the Research plus? Back to top
    As each Research plus pipette has been calibrated and adjusted before delivery, the adjustment display shows "0". As soon as the adjustment is changed by the user, the reading on the display will be changed, too. Therefore, the adjustment display provides optical control if a pipette has been adjusted to another volume.
    What do I have to observe regarding maintenance and cleaning of the Research plus? Back to top
    The Research plus pipettes are easy to clean. Only the lower part should be cleaned on a regular basis, in accordance with the frequency of use. The lower part of the single-channel and multi-channel Research plus pipettes can be removed easily as described in the operating manual of the Research plus or in our Application Note 198. (http://www.eppendorf.de/int/index.php?sitemap=4.1&pb=f69dc5897412b7d4&action=support&contentid=1&catalognode=67026&productpage=7)
    When should the spring loading of the single-channel Research plus pipettes be deactivated? Back to top
    For dispensing tasks in which a pipette tip is used over a long time or is slightly bended, it can be helpful to deactivate the spring loading of the tip cone by installing the locking ring. This can also be helpful for pipette tips which are not designed for the Eppendorf pipette cones.

    POCD Scientific ~ Eppendorf’s Australian distributor for Research® plus adjustable pipettes ~ videos



    Video Title inserted here on selection
    videos courtesy Eppendorf UK

    Video will appear here once selected

    press play to
    start video
    brought to you by brought to you by POCD Scientific

    Videos available

    Forward Pipetting Forward Pipetting with the Research plus adjustable   Reverse Pipetting with the Research plus adjustable Reverse Pipetting with the Research plus adjustable
    Leak testing the  Research plus adjustable Leak testing the Research plus adjustable Autoclaving the  Research plus adjustable Autoclaving the Research plus adjustable
    Assembling the Research plus Assembling the Research plus Disassembling the Research plus Disassembling the Research plus
    Replacing the O-rings in  the  Research plus Replacing the O-rings in the Research plus Deactivating the  Research plus adjustable spring-loaded tip Deactivating the Research plus adjustable spring-loaded tip


    Related Pages

    Comparison of pipette user-friendliness   Pipette user-friendliness
    A comparison of user-friendly operating features, which reduce strain during pipetting
      Comparison of pipette user-friendliness   Research Plus adjustment & maintenance
    Insider tips and tricks to get the most out of your Research Plus pipette.

    Back to top or call 1800 640 075 free


    Middle Path Online logo website by
    Middle Path Online
    pocdscientific.com.au/Eppendorf_Research_Plus_pipette_adjustable.php       updated August 22nd,2012
    ©2013 POCD Pty Ltd,     T/A POCD Scientific ABN 93 067 939 824
    product information, images and video gratefully used with permission of manufacturers.